API credential, entered client by client.

Connects the Rapid7 InsightVM Security Console (API v3) to read covered assets, open vulnerabilities by severity and scan freshness, site by site. It reads the console the client hosts, not the Insight cloud API, whose response envelope is unpublished. Machines outside the configured sites are covered by no count.

01

What to create in the tool

The access is created in Rapid7 InsightVM, not in Vigicap. Vigicap never asks for an administrator's password: it expects an API credential that you create, that you can see, and that you can revoke without us.

Where to generate it

Créez dans InsightVM un compte avec le rôle « Read Only ». Adresse de l'instance : l'URL de votre Security Console, port compris (ex : https://insightvm.exemple.fr:3780).

Minimum role

The minimum role this connector needs is not documented to date. We would rather write that than guess it: an unverified claim about access rights ends up in front of a client's data protection officer, who is precisely the person who will check it. Refer to the vendor's documentation, which alone is authoritative on its role model.

02

What to enter in Vigicap

The exact fields of the connection form, in the order they appear. Values marked “secret” never travel back to the browser: they are encrypted at rest and deleted on disconnection.

The form starts with the instance address, entered separately from the fields below. The public catalogue does not yet publish whether this connector needs one, or what it looks like — so this list is exact about everything else, and silent about that first field.

  • Identifiant

    Compte de la Security Console, rôle « Read Only » de préférence.

  • Mot de passesecret

    Mot de passe du compte ci-dessus.

03

Per-client routing

The connection is made client by client: one credential per client, entered on that client's record. Nothing is shared between two clients, and disconnecting one leaves the other untouched.

04

What it does, and what it does not do

ReCyF objectives it pre-fills

A reading feeds 2 objectives of the ANSSI ReCyF framework. It PROPOSES them: a level only counts once a consultant has confirmed it.

  • #5 Maîtrise des systèmes d'informationControl of the information systems
  • #17 Audit de la sécurité des systèmes d'informationAudit of information systems security

Read-only

The reads are read-only: Vigicap writes nothing into the tool while reading it.

What is read, what is kept, for how long and with which rights: the same register, connector by connector, in the data inventory.

Verification

The API is public and documented, but it can only be reached with a paid subscription the vendor issues no trial for: there is no instance we can obtain to run it against. This is not “not yet done” — it would take a customer lending us their tenant.

The trademarks and logos mentioned belong to their respective owners and identify the tools Vigicap is compatible with — see the legal notice.